Filter Fluorometers

Filter Fluorometer Ordering Information ] Fluorescence Detection Facts ] Filter Fluorometer Info Request ] Application Information ] System Features ] Filter Information ] OTD Instrument Pictures ]

 

 

Introduction

Optical Technology Devices, INC.
offers four high performance filter fluorometers, for a wide range of applications.  They represent  the latest technology for fluorescence detector instruments; in a line that has been developed by this company and its predecessor since 1965.

Applications

These instruments are for fluorescence assay procedures with fixed excitation and emission wavelengths.

Measures concentration levels of: NADH: NADPH, DNA, RNA, Protein: Peptides, Aflatoxin, ATP, Fluorescein based labeling, Rhodamine, Estrogen, Protease activity, Enzyme assays, Kinetic Intercellular measurement, Amino Acids, Vitamins, Drug-metabolites, Steroids, etc. Also fluorescence polarization measurements.

Application Information

Filter Information

Flourescence Detection Facts.

 

Features

System Features

Accurate for levels of fluorescein less then 1 pM.

Select minimum sample volume of 500, 80, 25 microliters.

Seven range positions, providing 1,000,000 : 1 dynamic range, for all excep the A1.

Excitation and emission filter holders are externally accessible.

Optical system uses five high quality 39mm diameter lenses.

Two high gain low noise photomultiplier tubes available- 200-700nm or 200-900nm.

Two of the four instruments incorporate a microprocessor.

Two 100 watt illumination sources available - mercury or a quartz halogen lamp.

Additional Information

 

Selecting The Right Filter Fluorometer

* A-1 Filter Fluorometer - for routine procedures

* Ratio-3 Filter Fluorometer- for all procedures with; automatic correction for illumination energy changes, seven range position for 1,000,000 : 1 dynamic range.

* Standard Curve Filter Fluorometer - for all procedures with: microprocessor, auto ranging, RS 232 and printer ports, calculates concentration levels from standard curve, automatic correction for illumination changes, seven auto-range positions for 1,000,000 : 1 dynamic range.

* Automatic Sampler System - incorporates Standard Curve Filter Fluorometer and a auto-sampler to automatically measure 96 samples within 14 minutes.  The 96 cells are arranged in the same configuration as 96 well microplates; so that loading instrumentation used for these plates can be used.

 

 

Pricing and Ordering Information

Pricing and ordering information can be found here.

 

 

 

 

 