Pluse Modulated Controls Distributed by:
MEK80-S / MEK80-H T&C Industrial Controls
The MEK 80 Series is a complete line of single channel pulse modulated photoelectric controls. These controls use a pulse counting technique that offers extreme immunity to noise and ambient light. Because of this technique response time is fast and accurate.  
MEK 80 Controls are available in both standard and high speed models. The MEK 80-S standard version is characterized by low scanner LED current (3mA). This results in efficiency and long LED life, without sacrificing distance. The MEK 80-H high speed version is characterized by a very fast 1 millisecond response time and low hysteresis.
MEK 80 Controls are available with any of five modes of time delay (see chart) and relay, open collector, or triac outputs. Any of the MEKontrol Scanners of thrubeam pairs can be used with these controls.
Features:Specifications:Dimensions (in.)
•   Ambient immunity
•   Long distance
•   High sesitivity
•   Low sensor current
•   Low power consumption
•   Repairable
•   Compatible with all MEK 80 sensors
Power input
115 VAC @ 15mA max.
Power to LED
100mA @ 3% duty cycle, 3mA average
Power to receiver
5 VDC
Output
Relay S.P.D.T. 5A @ 115 VAC
Triac 100mA @ 115 VAC
Open Collector 100mA @ 30 VDC
Sensitivity adjustment
15 turn pot
Temperature
Operating 0° to 60°C
Storage -40° to 70°C
Response Time
4 milliseconds (4 counts @ 1 kHz rate)
Hysteresis
10%
MEK 80-H Specifications:
Power to LED
100mA @ 13% duty cycle, 13mA average
Response Time
4 milliseconds (4 counts @ 1 kHz rate)
Hysteresis
5%

Wiring Diagram
Shown light energize - For dark energize jump 6 to 7

Timing Chart
All time delay .01 - 15 sec.
For other delay times consult factory

 
 
MODE A
Light energize
 
Dark energize
 
MODE B
Light energize
 
Dark energize
 
MODE C
Light energize
 
Dark energize
 
MODE D
Light energize
 
Dark energize
 
MODE E
Light energize
 
Dark energize
Ordering Information
MEK 80-  model   output   timing
Model Output Timing
 
S- Standard
H- High Speed
R- Relay
T- Low level triac
C- Open collector
X- No delay
A- Delay off
B- Delay on
C- Delay on/off
D- One shot
E- Delayed one shot