Distributed by: T&C Industrial Controls, Inc. |
Manufactured by: Mercury Switches, Inc. |
![]()
![]()
|
|
|
Coil Voltage: Standard voltages of 24V and 120V 50/60 Hz and 24V DC. Two and 3 pole coils in series.
Contact Load: For highly inductive and DC loads contact Mercury Switches Inc.
Pull-in Voltage: Typically less than 80% of nominal.
Drop-out Voltage: Approximately 4 volts less than pull-in voltage.
Timing: Contact closing or opening from 50 to 100 milliseconds.
Contact Resistance: Typically .005 Ohm.
Dielectric Withstand: 2500V R.M.S.
Life Expectancy: In excess of 1 million under normal conditions of temperature and load.
Temperature Range: -35 to +75 deg. C
Termination: 1/4" quick connect terminals.
U.L. Standard: Meets or exceeds UL & CSA requirements.
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
24NO-24A |
20 Amp 120V AC Resistive ONLY |
24V 50/60 Hz |
185 mA |
2.0W |
S.P.S.T.N.O. |
|
224NO-24A |
24V 50/60 Hz |
380 mA |
4.4W |
D.P.S.T.N.O. |
|
|
324NO-24A |
24V 50/60 Hz |
675 mA |
8.5W |
T.P.S.T.N.O. |
|
|
24NO-120A |
120V 50/60 Hz |
45 mA |
2.2W |
S.P.S.T.N.O. |
|
|
224NO-120A |
120V 50/60 Hz |
78 mA |
5.4W |
D.P.S.T.N.O. |
|
|
324NO-120A |
120V 50/60 Hz |
145 mA |
9.2W |
T.P.S.T.N.O. |
![]()
|
|
|
Coil Voltage: Standard voltages of 24, 120, 208/240, 277 and 480V 50/60 Hz and 24V DC. Other voltages on request.
Contact Load: For highly inductive and DC loads specify "H" units.
Pull-in Voltage: Under 90 volts for 120V 50/60 Hz. Typically less than 70% of nominal.
Drop-out Voltage: Approximately 2 volts less than pull-in voltage.
Timing: Contact closing or opening from 50 milliseconds.
Contact Resistance: Typically .003 Ohm.
Dielectric Withstand: 2500V R.M.S.
Life Expectancy: Mechanical - 25 million; Resistive Load - 5 million; Tungsten Lamp - 10,000 minimum.
Max. Load Cycling: 20 times per minute at 23 deg. C ambient (reduced life).
Temperature Range: -35 to +75 deg. C
Termination: Coil with #6 binding head screw. Load terminals with pressure connector for AWG #6-14 leads. Alternate terminals as shown on "T" units
Standard Listing: UL listed as Industrial Control Equipment E76691 (N). CSA 56002. Approval for 100,00 cycles endurance test. Temperature tested at 140 deg. F ambient. Undervoltage and increased voltage tests at 18 and 31V AC respectively for 24V AC coils.
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
35NO-120AH |
35 Amp 480V AC General purpose |
120V 50/60 Hz |
40 mA |
2.5W |
S.P.S.T.N.O. |
|
235NO-120AH |
120V 50/60 Hz |
80 mA |
5W |
D.P.S.T.N.O. |
|
|
335NO-120AH |
120V 50/60 Hz |
120 mA |
7.5W |
T.P.S.T.N.O. |
|
|
35NC-120AH |
120V 50/60 Hz |
55 mA |
3W |
S.P.S.T.N.C. |
|
|
235NC-120AH |
120V 50/60 Hz |
110 mA |
6W |
D.P.S.T.N.C. |
|
|
335NC-120AH |
120V 50/60 Hz |
165 mA |
9W |
T.P.S.T.N.C. |
For 35NO U.L. & CSA Rating: 35 Amp 600V AC Resistive (reduced life).
|
|
|
|
|
Units are functionally identical to 35NO/35NC series. Catalog numbers with suffix T, for example: 35NO-120AT, are with 1/4" allen cap screws. Numbers with suffix t, for example: 35NO-24At, are with 8-32 binding head screws for ring or spade terminals. T terminals receive AWG #8-14 leads. |
![]()
|
|
|
Coil Voltage: Standard voltages of 24, 120, 208/240, 277 and 480V 50/60 Hz and 24V DC. Other voltages on request.
Contact Load: For highly inductive and DC loads specify "H" units.
Pull-in Voltage: Under 90 volts for 120V 50/60 Hz. Typically less than 70% of nominal.
Drop-out Voltage: Approximately 2 volts less than pull-in voltage.
Timing: Contact closing or opening from 50 milliseconds.
Contact Resistance: Typically .002 Ohm.
Dielectric Withstand: 2500V R.M.S.
Life Expectancy: Mechanical - 25 million; Resistive Load - 5 million; Tungsten Lamp - 10,000 minimum.
Max. Load Cycling: 20 times per minute at 23 deg. C ambient (reduced life).
Temperature Range: -35 to +75 deg. C
Termination: Coil with #6 binding head screw. Load terminals with pressure connector for AWG #2-12 leads.
Standard Listing: UL listed as Industrial Control Equipment E76691 (N). CSA 56002. Approval for 100,00 cycles endurance test. Temperature tested at 140 deg. F ambient. Undervoltage and increased voltage tests at 18 and 31V AC respectively for 24V AC coils.
50 AMP CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
50NO-120AH |
50 Amp 480V AC General purpose |
120V 50/60 Hz |
40 mA |
2.5W |
S.P.S.T.N.O. |
|
250NO-120AH |
120V 50/60 Hz |
80 mA |
5W |
D.P.S.T.N.O. |
|
|
350NO-120AH |
120V 50/60 Hz |
120 mA |
7.5W |
T.P.S.T.N.O. |
|
|
50NC-120AH |
50 Amp 240V AC General purpose |
120V 50/60 Hz |
55 mA |
3W |
S.P.S.T.N.C. |
|
250NC-120AH |
120V 50/60 Hz |
110 mA |
6W |
D.P.S.T.N.C. |
|
|
350NC-120AH |
120V 50/60 Hz |
165 mA |
9W |
T.P.S.T.N.C. |
60 AMP CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
60NO-120AH |
60 Amp 480V AC General purpose |
120V 50/60 Hz |
40 mA |
2.5W |
S.P.S.T.N.O. |
|
260NO-120AH |
120V 50/60 Hz |
80 mA |
5W |
D.P.S.T.N.O. |
|
|
360NO-120AH |
120V 50/60 Hz |
120 mA |
7.5W |
T.P.S.T.N.O. |
|
|
60NC-120AH |
60 Amp 240V AC General purpose |
120V 50/60 Hz |
55 mA |
3W |
S.P.S.T.N.C. |
|
260NC-120AH |
120V 50/60 Hz |
110 mA |
6W |
D.P.S.T.N.C. |
|
|
360NC-120AH |
120V 50/60 Hz |
165 mA |
9W |
T.P.S.T.N.C. |
![]()
|
|
|
Coil Voltage: Up to 480V AC and 250V DC.
Contact Load: 80 Amp 480V AC Resistive.
Pull-in Voltage: Under 90 volts for 120V 50/60 Hz.
Drop-out Voltage: Approximately 5 volts less than pull-in voltage.
Timing: Contact closing or opening from 70 milliseconds.
Contact Resistance: Typically .001 Ohm.
Dielectric Withstand: 2500V R.M.S.
Life Expectancy: Mechanical - 25 million; Resistive Load - typically 5 million at room temperature and slow operating cycle.
Temperature Range: -35 to +75 deg. C
Termination: Coil with #6 binding head screw. Load terminals with pressure connector for AWG #2-8 leads. (larger size connectors available)
80 AMP CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
80NO-120AH |
80 Amp 480V AC General purpose |
120V 50/60 Hz |
150 mA |
8W |
S.P.S.T.N.O. |
|
280NO-120AH |
120V 50/60 Hz |
300 mA |
16W |
D.P.S.T.N.O. |
|
|
380NO-120AH |
120V 50/60 Hz |
450 mA |
24W |
T.P.S.T.N.O. |
|
|
80NC-120AH |
80 Amp 240V AC General purpose |
120V 50/60 Hz |
225 mA |
12W |
S.P.S.T.N.C. |
|
280NC-120AH |
120V 50/60 Hz |
450 mA |
24W |
D.P.S.T.N.C. |
|
|
380NC-120AH |
120V 50/60 Hz |
675 mA |
36W |
T.P.S.T.N.C. |
15 AMP HV CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
15HVO-120AH |
15 Amp 3500V AC Inductive 0.75pf |
120V 60 Hz |
150 mA |
8W |
S.P.S.T.N.O. |
|
215HVO-120AH |
120V 60 Hz |
300 mA |
16W |
D.P.S.T.N.O. |
|
|
315HVO-120AH |
120V 60 Hz |
450 mA |
24W |
T.P.S.T.N.O. |
|
|
15HVC-120AH |
10 Amp 3500V AC Inductive 0.75pf |
120V 60 Hz |
225 mA |
12W |
S.P.S.T.N.C. |
|
215HVC-120AH |
120V 60 Hz |
450 mA |
24W |
D.P.S.T.N.C. |
|
|
315HVC-120AH |
120V 60 Hz |
675 mA |
36W |
T.P.S.T.N.C. |
15 AMP 3500 VOLT MERCURY CONTACTORS:
The 80 Amp units - modified - are ideal for high voltage application such as UV lamp circuits. Dielectric withstand voltage exceeds 10000 VAC between load terminals and load and coil circuits. Pressure connectors for AWG #4-14 are provided. Dimensional data are identical to the 80 AMP units.
![]()
|
|
|
Coil Voltage: Up to 480V AC and 250V DC.
Contact Load: See below.
Pull-in Voltage: Under 90 volts for 120V 50/60 Hz.
Drop-out Voltage: 65% of rated voltage.
Timing: Contact closing or opening between 40 and 90 milliseconds.
Contact Resistance: Typically .001 Ohm.
Dielectric Withstand: 2500V R.M.S.
Life Expectancy: Mechanical - 25 million; Resistive Load - 5 million
Temperature Range: -35 to +70 deg. C
100 AMP CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
100NO-120AH |
100 Amp 480V AC General purpose |
120V 60 Hz |
190 mA |
11W |
S.P.S.T.N.O. |
|
2100NO-120AH |
120V 60 Hz |
380 mA |
22W |
D.P.S.T.N.O. |
|
|
3100NO-120AH |
120V 60 Hz |
570 mA |
33W |
T.P.S.T.N.O. |
CONTACT RATING PER POLE (RESISTIVE ONLY)
|
Volts 60 Hz |
Up to 240 |
277 |
480 |
600 |
|
Amps |
100 |
100 |
100 |
100 |
![]()
150 AMP CONTACTOR
|
Cat. No. |
Load Rating Per Pole |
Coil Voltage |
Coil Current |
Coil Power |
Contact |
|
150NO-120AH |
150 Amp 120V AC General purpose |
120V 60 Hz |
190 mA |
11W |
S.P.S.T.N.O. |
|
2150NO-120AH |
120V 60 Hz |
380 mA |
22W |
D.P.S.T.N.O. |
|
|
3150NO-120AH |
120V 60 Hz |
570 mA |
33W |
T.P.S.T.N.O. |
CONTACT RATING PER POLE (RESISTIVE ONLY)
|
Volts 60 Hz |
Up to 240 |
277 |
480 |
600 |
|
Amps |
150 |
140 |
130 |
120 |
![]()
|
Distributed by: T&C Industrial Controls, Inc. |