DELAY ON BREAK SELECTION GUIDE

Distributed by: T&C Industrial Controls, Inc.
1121 N. Cedar St. * Glendale, CA 91207 USA
(818) 240-3600 * FAX (818) 547-9359
Email to: tcindust@flash.net

Manufactured by: SSAC Inc.
P.O. Box 1000 * Baldwinsville, NY 13027
(315) 638-0333 * FAX (315) 638-7158

 

Time Delay Relays

Timing Modules

Power Timing Modules

Isolated Timing Modules

TIME DELAY RELAYS

 

DESCRIPTION

TIME DELAY

OUTPUT

APPROVAL

TDB Series:
Digital circuitry provides very accurate and stable timing. Ten binary coded switches set time delay within ±2%. LED indication and plug-in base (8 or 11 pin). Panel mount kit available (BZ1).

0.1 second to 170.5 minutes in 3 ranges

SPDT or DPDT, 10 amperes

UL, CSA

TRDU Series:
Versatile time delay relay with twenty-one selectable single and dual modes of operation. Switch selectable mode and timing range. Two LED's indicate input power and output status. Octal and Magnal plug-in. Panel mount kit available (BZ1).

0.1 second to 1705 hours in 8 ranges

SPDT or DPDT, 10 amperes

UL, CSA, CE

TRU Series:
Totally Universal Microcomputer based Time Delay Relay. Operating voltage 19-264 VAC and 19-30 VDC. Multifunction: Delay on Make, Interval, Single Shot, Delay on Break, Recycling, Retriggerable Single Shot, Knob Adjustable; with range selector switch. Slide switch function selector.

0.1 second to 1000 minutes in 6 ranges

SPDT or DPDT, 10 amperes

UL, CSA

TDMB Series:
Combines both delay on make and delay on break into one plug-in (8 or 11 pin) unit. Both delays are functional, not selectable, and are independently adjustable via dual 10 position binary coded switches. AC voltages only. Panel mount kit available (BZ1).

0.1 second to 170.5 minutes in 3 ranges

SPDT or DPDT, 10 amperes

UL, CSA

TRB Series:
Standard knob adjustable, time delay relay with 8 or 11 pin plug-in base. Available with fixed, remote, or onboard adjustment. Can be ordered with one of three factory calibrated tolerances of 5, 10, or 20 percent. Panel mount kit available (BZ1).

0.05 to 600 seconds in 15 ranges

SPDT or DPDT, 10 amperes

UL, CSA

PRLB Series:
Low cost, knob adjustable time delay relay with octal (8 pin) plug-in base. Guaranteed time range for non-critical timing applications. Available for AC and DC voltages. Panel mount kit available (BZ1).

0.05 to 600 seconds in 6 ranges

SPDT, 10 amperes

UL, CSA

HRDB Series:
Isolated SPST, 15 ampere output contacts for direct operation of load. Knob adjust, factory fixed, or remote adjustment. Encapsulated accurate digital circuitry. 1/4" quick-connect terminals. Cost effective.

0.2 second to 100 minutes in 5 ranges

SPST normally open, 15 amperes

UL, CSA

ORB Series:
Features analog circuit and open board construction for reduced cost. Factory fixed, onboard, or remote time adjustments. 1/4" quick-connect terminals. AC voltages only.

0.05 second to 300 seconds in 5 ranges

SPDT or DPDT, 10 amperes

UL, CSA

Time Delay Relays

Timing Modules

Power Timing Modules

Isolated Timing Modules

TIMING MODULES

 

DESCRIPTION

TIME DELAY

OUTPUT

APPROVAL

ASQU/ASTU or DSQU/DSTU Series:
Universal timer with 5 modes of operation, knob adjustable (ASQU/ASTU) or switch adjustable (DSQU/DSTU) time delay, and universal voltage operation of 24 to 240 VAC or 9 to 135 VDC. Its 17.5 mm enclosure may be surface or 32 & 35 mm DIN rail mounted. Available with 0.25 inch (6.35 mm) quick-connect terminals (ASQU/DSQU) or 0.197 inch (5 mm) push-on terminal blocks (ASTU/DSTU).

ASQU/ASTU: 0.1 second to 100 minutes in 4 ranges
DSQU/DSTU: 0.1 second to 63 minutes in 4 ranges

Solid State, 0.7 ampere, normally open

UL, CSA, CE

TDUB Series:
Accurate digital timing circuit with ten binary coded switches for selecting the delay. Wide AC/DC operating voltage with low, medium, or high time ranges. Encapsulated with 1/4" quick-connect terminals.

0.1 second to 2.8 hours in 3 ranges

Solid State, 1 ampere

UL, CSA

TSB Series:
Reliable analog time delay module with encapsulated circuit. Factory fixed or remote adjust. Features continued timing with loss of power. 1/4" terminals for series connection with load. Very cost effective.

0.05 to 600 seconds in 4 ranges

Solid State, 1 ampere

UL, CSA

TSDB Series:±1% KSDB Series:±10%
Digital circuit provides excellent repeat accuracy and extended time delays. The time delay can be factory fixed or externally adjusted. The circuit is encapsulated. 1/4" quick-connect terminals.

0.1 second to TSDB 16.6 hrs. in 6 ranges KSDB to 500 minutes in 5 ranges

Solid State, 1 ampere

Both: UL KSDB: CSA

TSD7 Series:
Only two terminals series connection with load. Provides interval or delay-on-break timing. The digital circuit provides good accuracy. Factory fixed or externally adjusted delay. Terminates with 1/4" quick-connect. Encapsulated. Only AC voltages.

1 second to 1000 minutes in 5 ranges

Solid State, 1 ampere

UL, CSA

Time Delay Relays

Timing Modules

Power Timing Modules

Isolated Timing Modules

POWER TIMING MODULES

 

DESCRIPTION

TIME DELAY

OUTPUT

APPROVAL

THB Series:
Economical analog circuitry with high current solid-state output. Eliminates the need for separate relay and timer. Encapsulated with metallized mounting surface for transfer of heat. Remote adjust or factory fixed delays. 1/4" quick-connect terminals.

0.1to 600 seconds in 4 ranges

Solid State, 6, 10, or 20 amperes

CSA

THDB Series:
Digital circuitry combined with high current solid-state output. Encapsulated with metallized mounting surface for transfer of heat. Remote adjust or factory fixed delays. 1/4" quick-connect terminals.

0.1 second to 1000 minutes in 6 ranges

Solid State, 6, 10, or 20 amperes

UL, CSA

THD7 Series:
Only two terminals series connection with load. Provides interval or delay-on-break timing. Factory fixed or adjustable. Encapsulated circuit. 1/4" quick-connect terminals. AC voltages only.

1 second to 1000 minutes in 5 ranges

Solid State, 6, 10, or 20 amperes

UL, CSA

Time Delay Relays

Timing Modules

Power Timing Modules

Isolated Timing Modules

ISOLATED TIMING MODULES

 

DESCRIPTION

TIME DELAY

OUTPUT

APPROVAL

EISB Series:
Totally solid-state timing module with electrical isolation between input and output (1500 Volts RMS). The digital timing circuit is completely encapsulated. Control voltage can be AC or DC. AC loads only. Remote adjust or factory fixed delays.

0.2 second to 1000 minutes in 6 ranges

Solid State, 1 ampere

 

Time Delay Relays

Timing Modules

Power Timing Modules

Isolated Timing Modules

 

Distributed by: T&C Industrial Controls, Inc.
1121 N. Cedar St. * Glendale, CA 91207 USA
(818) 240-3600 * FAX (818) 547-9359
Email to: tcindust@flash.net

Manufactured by: SSAC Inc.
P.O. Box 1000 * Baldwinsville, NY 13027
(315) 638-0333 * FAX (315) 638-7158