| 1. |
Output |
|
1.1 |
Solid state modulating phase control |
|
1.2 |
Rating: |
|
1.3 |
Heat Sink: The back of the 6, 10, and 20 ampere units are metallized to provide a method of
transferring heat from the package to a metal heat sink (mounting surface). 90°C maximum plate temperature |
|
1.4 |
Minimum Load Current: 100 milliamperes |
|
1.5 |
Voltage Drop: 2.0 volts typical at rated current |
| 2. |
Input |
|
2.1 |
Nominal Voltage: 120, or 230 VAC |
|
2.2 |
Tolerance: ±20% of nominal |
|
2.3 |
Frequency: 50/60 Hz |
| 3. |
Protection |
|
3.1 |
Dielectric Breakdown: Greater than 1500 volts RMS |
|
3.2 |
Insulation Resistance: 100 megohms minimum |
|
| 4. |
Environmental |
|
4.1 |
Operating Temperature: -20°C to +60°C |
|
4.2 |
Storage Temperature: -40°C to +85°C |
|
4.3 |
Humidity: 95% relative, non-condensing |
| 5. |
Adjustments |
|
5.1 |
120VAC: Use a 100k ohms at 1 watt potentiometer for external adjustment |
|
5.2 |
230VAC: Use a 200k ohms at 2 watts potentiometer for external adjustment |
|
5.3 |
External adjustments must have insulation resistance suitable for line voltage applications |
| Potentiometer |
 |
|
| Part Number |
Value (Ohms) |
| P1004-174 |
100k |
| P1004-175 |
200k |
| A durable conductive plastic potentiometer. Recommended for use with the
PHS Series. It is designed to withstand high temperature and harsh environments. The shaft is slotted for screwdriver
adjustment and can be panel mounted. |
| |
Resistance values 100k and 200k ±10% |
| |
Rated 2 watts at 70°C |
| |
Linear taper |
| |
Shaft rotation: 312° ±3° (effective rotation 275° ±5°) |
|
|
| CONNECTION |
OPERATION |
 |
Upon application of power (switch closure), effective output voltage can be varied by
changing the external adjustment value. As the external resistance increases, the effecive output voltage decreases.
The inverse is also true. |
Typical output wave form:
 |
MECHANICAL

| | 1 Amp Units |
All Others |
| L | 1.21 |
1.51 |
| M | 0.75 |
1.08 |
|
| Note: Unit must be mounted to metal surface for proper dissipation.
Heat sink compound provided with each unit. |
| Note: All dimensions in inches. |
|
| ORDERING INFORMATION |
| Select One From Each Column Bold Items Are Included In Part Number |
| Series |
Operating Voltage |
Rating (in amperes) |
| PHS |
120A -120VAC 230A -230VAC |
1 6 10 20 |
Example Part Number: PHS120A10 is an AC Phase Control for operation
at 120 volts AC line with load current rating of 10 amperes.
| |